Features
Description
Specification
CR Series
Item
CR-0802/CR-0802-N
CR-0802D/CR-802D-N
CR-1002/CR-1002-N
CR-1002D/CR-1002D-N
CR-1202/CR-1202-N
CR-1202D/CR-1202D-N
Dimension
5310*1353*1490mm
5310*1583*1490mm
6100*1353*1490mm
6100*1583*1490mm
6915*1353*1490mm
6915*1583*1490mm
No. of Heating zone
top8/bottom8
top10/bottom10
top12/bottom12
Length of heating zone
3110mm
3890mm
4706mm
Length of cooling Zone
800mm
No. of cooling zone
Top/2
Extraction
10m3/min*2
Max PCB size
400mm(option: 460mm)
610mm(option:686mm)
400mm(option:460mm)
Conveyor Direction
L→R (option R→L)
Fixed rail side
Front Rail Fixed (Option: Rear Rail Fixed)
Conveyor Height
900±20mm
Component Height
PCB top/bottom 25mm (option PCB top30mm/bottom25mm)
Conveyor Speed
300-2000mm/min
Chain spec
Single Strand Chain
Rail width Adjust Mode
By Manual + by Motor
Rail structure
Subsection Integrated type
Power supply
3 φ 380 V 50/60 Hz (3 φ 220V 50/60Hz) subject to technical agreement)
Total power
64KW/67KW
80KW/83KW
89KW/92KW
93KW/96KW
101KW/104KW
Startup power
28KW/30KW
32KW/34KW
34KW/36KW
36KW/38KW
40KW/42KW
Normal power consumption
10KW/11KW
11KW/12KW
12KW/13KW
13KW/14KW
Warming time
Approx.30min
Approx.35min
Temperature setting Range
Room Temperature -------300Deg/c
Temperature Control Pression
± 1Deg/c
Temperature Control Type
PID Close Loop control +SSR Driven
Temperature Deviation on PCB
±1.5Deg/c
Max. temp. Difference between preheat Zone and Solder Zone
80Deg/c
Max. temp. Difference between Preheat Zone
40Deg/c
Max. temp. Difference between Solder Zone
Data Storage
Process Data and Status Storage Unlimited
Alarm Display
By Sound and Light
Flux Service Hints
Software Hints Service period
N2 Consumption (Standard machine)
18-20m³/hr 300-1000PM
N2 Consumption (Extended machine)
25-30m³/hr 500-1000PM
Other Products in this Category